To eliminate the impact of radiation shower on the incremental encoder readout and provide a better dynamic movement the upgrade of all 88 phase shifters of the European XFEL have been successfully done without interruption of the operation schedule. The implementation steps, as well as the results of the hardware and software tests made in the laboratory, are presented. The sensitivity of the Renishaw RGH22O15D00A encoder to the radiation shower was measured in the SASE3 undulator system, and the results are presented.